<feat> v0.8.0, compatible with odin1 firmware version 0.9.0
1. Update api lidar_get_version which now return a data structure for detailed device firmware version info. Allowed force exit when device firmware version is lower than required. 2. Removed custom_save_map parameter from config yaml to reduce confusion. Added description on how to use it properly instead. 3. Added print message on relocalization sucess, indicated by recieve LIDAR_DT_SLAM_ODOMETRY_TF data type from device
This commit is contained in:
@@ -2,7 +2,7 @@
|
||||
|
||||
ROS driver suite for Odin sensor modules (Manifold Tech Ltd.)
|
||||
|
||||
Odin1 wiki: https://manifoldtehltd.github.io/wiki/Odin1/Cover.html
|
||||
Odin1 wiki: https://manifoldtechltd.github.io/wiki/Odin1/Cover.html
|
||||
|
||||
## Odin_ROS_Driver
|
||||
|
||||
@@ -18,7 +18,9 @@ This driver package provides core functionality for point cloud SLAM application
|
||||
|
||||
## 1. Version
|
||||
|
||||
Current Version: v0.7.1
|
||||
Current version: v0.8.0
|
||||
|
||||
Required device firmware version: v0.9.0
|
||||
|
||||
## 2. Preparation
|
||||
|
||||
@@ -262,7 +264,7 @@ float32 x // X axis, in meters
|
||||
float32 y // Y axis, in meters
|
||||
float32 z // Z axis, in meters
|
||||
uint8 intensity // Reflectivity, range 0–255
|
||||
uint16 confidence // Point confidence, range 0–65535
|
||||
uint16 confidence // Point confidence, actual value range from 0 to around 1300 in typical scene, higher value means more reliable. Recommanded filtering threshold is 30-35, should be adjusted accordingly.
|
||||
float32 offset_time // Time offset relative to the base timestamp unit: s
|
||||
```
|
||||
|
||||
@@ -438,6 +440,40 @@ Disable odin1/image with sendrgb = 0 in control_command.yaml and try again. If t
|
||||
|
||||
Purge the unused version of opencv and maintain a single complete version, then rebuild the driver and try again.
|
||||
|
||||
### 5.10 ROS Driver printing "TF_OLD_DATA ignoring data" warning
|
||||
|
||||
**Error Message**
|
||||
|
||||
```shell
|
||||
[rviz2-3] Warning: TF_OLD_DATA ignoring data from the past for frame odin1_base_link at time 20.547632 according to authority Authority undetectable
|
||||
[rviz2-3] Possible reasons are listed at http://wiki.ros.org/tf/Errors%20explained
|
||||
[rviz2-3] at line 294 in ./src/buffer_core.cpp
|
||||
```
|
||||
|
||||
**Reason**
|
||||
|
||||
This is a ros & rviz feature to warn user that some tf data is being ignored due to timestamp conflicts. It happens when user keeps ros driver running and power-cycles odin device, which cause odin's internal system time being reset and now data timestamps conflicts with old data recieved by rviz during last run.
|
||||
|
||||
**Resolution**
|
||||
|
||||
There's a reset button on bottom of rviz gui. Click on this button will reset rviz's internal state and stop the warning.
|
||||
|
||||
### 5.11 ROS Driver printing "unknown cmd code: xx" error
|
||||
|
||||
**Error Message**
|
||||
|
||||
```shell
|
||||
<ERROR><api.cpp:cmd_data_deal:418>: unknow command code 21.
|
||||
```
|
||||
|
||||
**Reason**
|
||||
|
||||
This is due to ros driver version mismatch with device firmware version, resulting in ros driver unable to decode new data added in newer firmware.
|
||||
|
||||
**Resolution**
|
||||
|
||||
Please make sure you are using most up-to-date ros driver and device firmware.
|
||||
|
||||
## 6. Contact Information
|
||||
|
||||
You can contact our support through support@manifoldtech.cn
|
||||
|
||||
Reference in New Issue
Block a user